CT PELVIS NON CONTRAST

Last Updated on February 15, 2022 by Mohamad Izwan

Author: Nabilah Nawi


Protocol Structure

00_PelvisRoutine (Adult)​

  • Topogram
  • Pelvis

Topogram

Cover from above iliac crest to symphysis pubis


Non Contrast

Vertically: From L5 to symphysis pubis

Horizontal: include bilateral pelvic soft tissue


Reconstruction Non Contrast

 Recon 1Recon 2
NameFacial IV 5.0 H30sFacial IV 1.0 H30s
KernelH30s medium smoothH30s medium smooth
WindowingBase OrbitaBase Orbita
Slice Thickness5.0mm1.0mm
Increment5.0mm1.0mm

Injector Setting

N/A


Multi Planar Reconstruction (MPR)

Parallel Ranges:

  • Image thickness : 3.0mm
  • Number of images : 19

Non Contrast Bone

  • Coronal 
  • Sagittal

Series of Images Send to PACS

Siemens SyngoVia 3D Render

Open with CT Bone Reading

Open ‘Range Tools’ choose ‘Radial Range’

Radial Range
Number of images = 19 (lock)
Angle between images= 19

Orientation:

Start from AP view. Then click ‘Start’

Save as VRT Range CT Pelvis Tilt

Open with CT Bone Reading

Open ‘Range Tools’ choose ‘Radial Range’

Radial Range
Number of images = 19 (lock)
Angle between images= 19

Orientation:

Choose set axis horizontal

Start from AP view. Then click ‘Start’

Save as VRT Range CT Pelvis